- home > Product >KVVRP Underground corrosion resistant the control cable GB double jacket KTVR cable manufacturers
Product Name: | KVVRP Underground corrosion resistant the control cable GB double jacket KTVR cable manufacturers |
Published: | 2013-03-26 |
Product Type: | Complete |
Product Description: | Executive Standard: This product is based on "plastic insulated control cables" GB / T 9330-2008 and enterprise standard Q / the HHD 008-2008 design manufacturing. Product characteristics, the main purpose and use characteristics: This product is AC rated voltage U0 / U for 0.6/1kV and under control, monitor and protect the loop line and other occasions to use the control cables are widely used in metallurgy, petroleum, chemical, electric power electrical instrumentation and power distribution equipment industry fixed installation or mobile laying cable. The cable on the security of supply and production of the normal operation of the system, its function is sometimes even more than the mainline power cable. Its main features are as follows: (1) Rated voltage U0 / U is 450/750V or 0.6/1kV. ② PVC insulated cable conductor long-term allowable working temperature of 70 ° C, the cable conductor XLPE insulation allows a working temperature of 90 ° C. ③ fixed laying cable conductor stranded conductor GB / T 3956-1997 first round solid core conductor or the second round; mobile laying flexible cable conductor using GB / T 3956-1997 five kinds soft circular stranded conductor. The ④ cable laying temperature should not be lower than 0 ° C lower than the temperature of the cable should be preheated. ⑤ cable bending radius - unarmored cables should be no less than six times the cable diameter; - armored or copper tape screened cable should be no less than 12 times the cable diameter; - shield structure of soft PVC insulated cable bend radius should be no less than six times the cable diameter. ⑥ finished cable 5min AC voltage 3500V test shall withstand without breakdown. The ⑦ products if any combustion characteristics and requirements should be in line with the "General Principles of flame-retardant and fire-resistant wire and cable, GB / T 19666-2005. Its product representation methods such as: Z (R) * (N *)-KVV 7 × 1.5 Q / HHD 008-2008 flag "*" represents retardant properties Level A, B, and C, D, etc.. The model number and the name of the cable as shown in Table 1, Table 2: Table 1 Model Name KVV PVC insulated PVC sheathed control cable KVVP PVC insulated and sheathed braid shield control cable KVVP2 PVC insulation and PVC sheathed copper tape shield control cable KVVP3 PVC insulated PVC sheathed plastic composite tape shielded control cable KVV22 PVC insulated PVC sheathed control cable KVVP2-22 PVC insulated PVC sheathed copper shielded steel tape armored control cable KVV32 PVC insulated PVC sheathed fine steel wire armored control the cable KVVR PVC insulated PVC sheathed control the flexible cable KVVRP PVC insulated PVC sheathed braided shield Table 2 Model Name KYJV XLPE insulated PVC sheathed control cable KYJVP XLPE insulated PVC sheathed braid shield control cable KYJVP2 XLPE insulated PVC sheathed copper tape shielded control cable KYJVP3 XLPE insulated PVC flexible control cable sheathed plastic composite tape shielded control cable KYJV22 XLPE insulated PVC sheathed control cable Table 2 (continued) KYJY XLPE insulated polyolefin sheathed control cable KYJYP XLPE insulated polyolefin sheathed braid shield control cable KYJYP2 XLPE insulation and polyolefin sheath copper tape shield control cable KYJYP3 XLPE insulated polyolefin sheathed plastic composite tape shielded cable KYJY23 XLPE insulated polyolefin sheathed control cable KYJYP2-23 XLPE insulated PVC sheathed copper shielded steel armored control cable KYJY33 XLPE insulated polyolefin sheathed fine steel wire armored control cable KYJVP2-22 XLPE insulated PVC sheathed copper shielded steel tape armored control cable KYJV32 XLPE insulated PVC sheathed fine steel wire armored control cable Note: Model can be carried out according to the actual requirements of the user the combination cable production range, such as in Table 3, Table 4, Table 3 Model conductor nominal cross section / mm2 0.5 0.75 1.0 1.5 2.5 4 6 10 core KVV KVVP - 2 to 61 2 to 14 2 ~ 10 KVVP2, KVVP3 - 4 ~ 61 4 ~ 14 4 ~ 10 KVV22 - 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KVVP2-22 - 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KVV32 - 19 ~ 61 7 ~ 61 4 ~ 14 4 ~ 10 KVVR 2 ~ 61 - KVVRP 2 ~ 61 2 ~ 48 - for table the 4 models conductor nominal cross section / mm2 0.75 1.0 1.5 2.5 4 6 10 core the number KYJV KYJVP KYJY KYJYP 2 to 61 2 ~ 14 2 ~ 10 KYJVP2 KYJVP3 KYJYP2 KYJYP3 4 ~ 61 4 ~ 14 4 ~ 10 KYJV22 KYJY23 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KYJVP2-22 KYJYP2-23 7 ~ 61 4 ~ 61 4 ~ 14 4 10 KYJV32 KYJY33 19 ~~ 61 7 61 4 14 4 10 Note: Recommended core number series: 2,3,4,5,7,8,10,12,14,16,19,24,27,30 , 37,44,48,52,61 cable Ordering instructions when ordering, you need to state the product name, model specifications, standard number; 2. delivered according to the length of the agreement; 3. measurement of the length tolerance does not exceed ± 0.5% . Cable storage and transportation: 1. Cables should be avoided open storage does not cover the case. Cable reel non-flat (the circular end of the cable tray down). 2. Temporary stand into a disk cables should be neatly and labeled models, specifications, voltage, length side outward or the channel placed, in order to find. Between the cable tray should channel storage foundation should be solid. When the conditions imposed under the disk should be padded, and the depository shall not be water. Cable in custody, cable tray and packaging should be in good condition, the logo should be complete, end-capping should be tight. When defective, should be timely treatment. After the cable is cut off, the remaining cable is not used immediately, must be cut mouth sealed to prevent moisture or water. Cable tray need to scroll, confirm the right direction of the arrow shown on the side of the cable tray (along the cable wrapped tightly in the direction of the cable tray), shown by the arrows to scroll. Cable tray in the transport of the car, placed should be straight force into the T-shaped, and prevent collisions, overturned flat cable reel non Remove the rear. Our solemn declaration: 1, Product Quality Assurance books signed, commitment - never factory substandard products. 2, within two years of product quality tracking service, and customer service records in the archives for 20 years. Indeed due to the problem of product quality, our factory warranty, refunding, replacement, to meet customer requirements. Specifications: customized according to customer requirements Quantity: the MOQ 100 m, 100 m -200 m floating Package Description: a few meters short of disc packaging meter long cable shaft packing Price Description: Phone deliberations, the price According to the decline in copper prices go up at any time to update Contact Sales (general manager) Wang Wenxu phone No. 15731627778 15731627778 office landline 0316-5726723 |
Admin>>>
You are the 1451356 visitor
Copyright © GuangDong ICP No. 10089450, The first branch of Tianjin Cable Plant cable plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 1451356 visitor
Copyright © GuangDong ICP No. 10089450, The first branch of Tianjin Cable Plant cable plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility