Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9211503
| No.9211503
- Product Categories
- Control Cable
- Rubber cables
- Power cable
- Computer shielded cable
- Shielded cable
- Mine Cable
- Mine communication cable
- Mine control circuit
- Railway signal cables
- Friendly Links
- home > Supply > Supply of control cable long-term supply KVVP2 three-core copper shielded control cable
| Information Name: | Supply of control cable long-term supply KVVP2 three-core copper shielded control cable |
| Published: | 2013-06-15 |
| Validity: | 30 |
| Specifications: | Complete |
| Quantity: | |
| Price Description: | |
| Detailed Product Description: | Standard: This product is based on "plastic insulated control cable" GB / T 9330-2008 and enterprise standard Q / HHD 008-2008 design and manufacturing. Product characteristics, the main purpose and use of features: This product is AC rated voltage U0 / U is 0.6/1kV and under control, monitor and protect the loop line and other occasions to use control cables are widely used in metallurgy, petroleum, chemical, power, etc. industry fixed installation or mobile laying power distribution equipment, electrical instrumentation cable. The cable for the security of electricity supply and the normal operation of the production system, its function and sometimes even more than the main trunk with a power cable. Its characteristics are as follows: ① Rated voltage U0 / U is 450/750V or 0.6/1kV. ② PVC insulated cable conductor is allowable working temperature of 70 ℃, XLPE insulated cable conductor long-term allowable working temperature is 90 ℃. ③ fixed laying cable conductors using GB / T 3956-1997 the first one kind of round solid conductor or the first two kinds of circular stranded conductor; mobile laying flexible cable conductor is GB / T 3956-1997 the first five kinds soft, round stranded conductors. ④ cable laying temperature should not be less than 0 ℃, the temperature below which the cable should be preheated. ⑤ cable bending radius - unarmored cable, not less than six times the cable diameter; - armored or copper tape screened cable should be not less than 12 times the cable diameter; - For there the shield PVC insulated flexible cable, the bending radius should not be less than six times the cable diameter. ⑥ 5min finished cable shall withstand 3500V AC voltage test without breakdown. ⑦ products should meet the requirements of any combustion characteristic "flame retardant and fire-resistant wire and cable General" GB / T 19666-2005. Representation of their products such as: Z (R) * (N *)-KVV 7 × 1.5 Q / HHD 008-2008 flag "*" represents fire performance class A, B, C, D and so on. Cable type and name as shown in Table 1, Table 2: Table 1 Model name KVV PVC insulated and sheathed control cable KVVP braided shield PVC insulated and sheathed control cable PVC insulated KVVP2 sheathed copper tape shield control cable KVVP3 PVC insulated plastic composite tape shielded control cable KVV22 PVC insulated sheathed control cable KVVP2-22 PVC insulated PVC sheathed copper shield steel tape armored control cable KVV32 PVC insulated, steel wire armored control cable KVVR PVC insulated and sheathed control cable PVC insulated and sheathed KVVRP braided shield control cable Table 2 Model Name KYJV XLPE insulated PVC sheathed control cable KYJVP XLPE insulated PVC sheathed braid shield control cable KYJVP2 XLPE insulated PVC sheathed copper tape screened control cable KYJVP3 XLPE insulated PVC Sheath plastic composite tape shielded control cable KYJV22 XLPE insulated PVC sheathed control cable TABLE 2 (continued) KYJY XLPE insulation and polyolefin sheath control cable KYJYP XLPE insulation and polyolefin sheath braided shield control cable KYJYP2 XLPE insulated PO sheathed copper tape shield control cable KYJYP3 XLPE insulation and polyolefin sheath plastic composite tape shielded cable KYJY23 XLPE insulated PO sheathed control cable KYJYP2-23 XLPE insulated PO sheathed copper shield tape armored control cable KYJY33 XLPE insulated PO sheathed fine steel wire armored control cable KYJVP2-22 XLPE insulated PVC sheathed copper shield steel tape armored control cable KYJV32 XLPE insulated PVC sheathed fine steel wire armored control cable Note: Product model according to the user's actual requirements for combination cable production ranges as shown in Table 3, Table 4 Table 3 Model Nominal cross section / mm2 0.5 0.75 1.0 1.5 2.5 4 6 10 cores KVV, KVVP - 2 ~ 61 2 ~ 14 2 ~ 10 KVVP2, KVVP3 - 4 ~ 61 4 ~ 14 4 ~ 10 KVV22 - 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KVVP2-22 - 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KVV32 - 19 ~ 61 7 ~ 61 4 ~ 14 4 ~ 10 KVVR 2 ~ 61 - KVVRP 2 ~ 61 2 ~ 48 - Table 4 Model Nominal cross section / mm2 0.75 1.0 1.5 2.5 4 6 10 Number of cores KYJV KYJVP KYJY KYJYP 2 ~ 61 2 ~ 14 2 ~ 10 KYJVP2 KYJVP3 KYJYP2 KYJYP3 4 ~ 61 4 ~ 14 4 ~ 10 KYJV22 KYJY23 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KYJVP2-22 KYJYP2-23 7 ~ 61 4 ~ 61 4 ~ 14 4 ~ 10 KYJV32 KYJY33 19 ~ 61 7 ~ 61 4 ~ 14 4 ~ 10 Note: The recommended number of cores Series: 2,3,4,5,7,8,10,12,14,16,19,24,27,30 , 37,44,48,52,61 cable Ordering Information 1. ordering, please indicate the product name, model specifications, standard number, etc.; 2. According to the agreement length delivery; 3. length measurement tolerance of less than ± 0.5% . Cable storage and transportation: 1. Cables should be avoided in the case of open storage does not cover. Cable tray is strictly prohibited flat (ie cable tray round face down). (2) temporary stand into a disk cable should be neatly and indicate type, size, voltage, length of one side or channel placed outside, in order to search. 3 cable tray should be between channels should be kept solid foundation. When subject to conditions, the disc should be added under the pad, and the depository may not have water. Cable in the custody period, the cable tray and packaging should be intact, labeling should be complete, should be tightly capped. When there are defects, should be timely treatment. Cable cut, the remaining cable is not used immediately, it must be cut mouth sealed to prevent moisture or water. 4 cable tray need to scroll, in recognition of the cable tray side direction of the arrow shown on the right (along the cable wrapped tightly to the cable tray in the direction), the direction of the arrow to scroll. 5 cable tray in the car transport, should be placed straight edge into the T-shaped and prevent collisions, overturning, remove the rear flat cable tray is strictly prohibited. Our solemn declaration: 1, signed product quality assurance and undertaking - substandard products not manufactured. Within two years, product quality tracking service, and customer service records in the archives of 20 years. 3 Ensure product quality problems, I will plant the warranty, refund, replacement, to meet customer requirements. Specifications: According to customer requirements Quantity: MOQ is 100 m, 100 m -200 m prices go up Packing: a few meters short of the disc packaging, a few meters long cable shaft packing Price Description: Phone negotiated price based on decline in copper prices go up at any time Updates Contact Sales Department (General Manager) Revise office phone number 15731627778 15731627778 landline 0316-5726723 |
Admin>>>
You are the 1451356 visitor
Copyright © GuangDong ICP No. 10089450, The first branch of Tianjin Cable Plant cable plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 1451356 visitor
Copyright © GuangDong ICP No. 10089450, The first branch of Tianjin Cable Plant cable plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

